Filters are designed for cleaning air and other gases, chemically inert to the materials of the body and the filter element, from mechanical impurities.
- 5 atm with the direction of filtration from the outside to the inside (products of the type FEN-Pr, FEA-Pr, FES-Pr);
- 2 atm with the direction of filtration from the inside to the outside (products of the FEN-Pr type).
- up to + 70 ° С
- 0.5 μm for FPRN-0.5 filters;
- 1.0 micron for FPRN-0.1 filters;
- 5 microns for FPRN-5.0 filters.
- 5.0 μm for FPRA-5.0 filters;
- 10.0 microns for FPRA-10.0 filters;
- 15.0 microns for FPRA-15.0 filters;
- 25.0 mm for filters of the type FPRA-25.0.
- 60 nm³ / h with a working pressure of 8 atm:
FPRN-0.5-KS-1-128 / P1-60;
FPRN-1.0-KS-1-128 / P1-60;
FPRN-5.0-KS-1-128 / P1-60;
ФПРА-5,0-КС-1-128 / П1-60;
FPRA-10.0-KS-1-128 / P1-60;
FPRA-15.0-KS-1-128 / P1-60;
FPRA-25.0-KS-1-128 / P1-60.
Replaceable filter elements:
FEN-Pr 0.5-128 / P1;
FEN-Pr 1.0-128 / P1;
FEN-Pr 5.0-128 / P1;
FEA-Pr 5.0-128 / P1;
FEA-Pr 10.0-128 / P1;
FEA-Pr 15.0-128 / P1;
FEA-Pr 25.0-128 / P1. - 140 nm³ / h with a working pressure of 8 atm:
FPRN-0.5-KS-1-128 / P-140;
FPRN-1,0-KS-1-128 / P-140;
FPRN-5,0-KS-1-128 / P-140;
FPRA-5,0-KS-1-128 / P-140;
FPRA-10.0-KS-1-128 / P-140;
FPRA-15.0-KS-1-128 / P-140;
FPRA-25.0-KS-1-128 / P-140.
Replaceable filter elements:
FEN-Pr 0.5-128 / P;
FEN-Pr 1.0-128 / P;
FEN-Pr 5.0-128 / P;
FEA-Pr 5.0-128 / P;
FEA-Pr 10.0-128 / P;
FEA-Pr 15.0-128 / P;
FEA-Pr 25.0-128 / P. - 280 nm³ / h with a working pressure of 8 atm:
FPRN-0.5-KS-1-254 / P-280;
FPRN-1,0-KS-1-254 / P-280;
FPRN-5,0-KS-1-254 / P-280;
FPRA-5,0-KS-1-254 / P-280;
FPRA-10.0-KS-1-254 / P-280;
FPRA-15.0-KS-1-254 / P-280;
FPRA-25.0-KS-1-254 / P-280.
Replaceable filter elements:
FEN-Pr 0.5-254 / P;
FEN-Pr 1.0-254 / P;
FEN-Pr 5.0-254 / P;
FEA-Pr 5.0-254 / P;
FEA-Pr 10.0-254 / P;
FEA-Pr 15.0-254 / P;
FEA-Pr 25.0-254 / P. - 400 nm³ / h with a working pressure of 40 atm:
FPRN-0.5-KS-1-128 / P-400;
FPRN-1.0-KS-1-128 / P-400;
FPRN-5.0-KS-1-128 / P-400;
FPRA-5,0-KS-1-128 / P-400;
FPRA-10.0-KS-1-128 / P-400;
FPRA-15.0-KS-1-128 / P-400;
FPRA-25.0-KS-1-128 / P-400.
Replaceable filter elements:
FEN-Pr 0.5-128 / P;
FEN-Pr 1.0-128 / P;
FEN-Pr 5.0-128 / P;
FEA-Pr 5.0-128 / P;
FEA-Pr 10.0-128 / P;
FEA-Pr 15.0-128 / P;
FEA-Pr 25.0-128 / P.
- 560 nm³ / h with a working pressure of 8 atm:
FPRN-0.5-KS-1-508 / P-560;
FPRN-1,0-KS-1-508 / P-560;
FPRN-5,0-KS-1-508 / P-560;
FPRA-5,0-KS-1-508 / P-560;
FPRA-10.0-KS-1-508 / P-560;
FPRA-15.0-KS-1-508 / P-560;
FPRA-25.0-KS-1-508 / P-560.
Replaceable filter elements:
FEN-Pr 0.5-508 / P;
FEN-Pr 1,0-508 / P;
FEN-Pr 5.0-508 / P;
FEA-Pro 5.0-508 / P;
FEA-Pr 10.0-508 / P;
FEA-Pr 15.0-508 / P;
FEA-Pr 25.0-508 / P. - 800 nm³ / h with a working pressure of 40 atm:
FPRN-0.5-KS-1-254 / P-800;
FPRN-1.0-KS-1-254 / P-800;
FPRN-5.0-KS-1-254 / P-800;
FPRA-5,0-KS-1-254 / P-800;
FPRA-10.0-KS-1-254 / P-800;
FPRA-15.0-KS-1-254 / P-800;
FPRA-25.0-KS-1-254 / P-800.
Replaceable filter elements:
FEN-Pr 0.5-254 / P;
FEN-Pr 1.0-254 / P;
FEN-Pr 5.0-254 / P;
FEA-Pr 5.0-254 / P;
FEA-Pr 10.0-254 / P;
FEA-Pr 15.0-254 / P;
FEA-Pr 25.0-254 / P. - 1700 nm³ / h with a working pressure of 8 atm:
FPRN-0.5-KS-3-508 / P-1700;
FPRN-1.0-KS-3-508 / P-1700;
FPRN-5,0-KS-3-508 / P-1700;
FPRA-5,0-KS-3-508 / P-1700;
FPRA-10.0-KS-3-508 / P-1700;
FPRA-15.0-KS-3-508 / P-1700;
FPRA-25.0-KS-3-508 / P-1700.
Replaceable filter elements:
FEN-Pr 0.5-508 / P;
FEN-Pr 1,0-508 / P;
FEN-Pr 5.0-508 / P;
FEA-Pro 5.0-508 / P;
FEA-Pr 10.0-508 / P;
FEA-Pr 15.0-508 / P;
FEA-Pr 25.0-508 / P.
with a nominal air flow of 60 nm³ / h

Absolute working pressure, atm: 8
Air consumption, Nm³ / h, not more than: 60
Filter area: 180 cm²
Excessive operating pressure: no more than 8 atm
Initial pressure drop at nominal flow and size of penetrating particles:
0,085 atm → filter FPRN-0.5-KS-1-128 / P1-60;
0.080 atm. → filter FPRN-1,0-KS-1-128 / P1-60;
0,075 atm → filter FPRN-5,0-KS-1-128 / P1-60;
0.060 atm. → filter FPRA-5,0-KS-1-128 / P1-60;
0.060 atm. → filter FPRA-10.0-KS-1-128 / P1-60;
0.060 atm. → filter FPRA-15.0-KS-1-128 / P1-60;
0.060 atm → filter FPRA-25.0-KS-1-128 / P1-60.
Final pressure drop:
not more than 1.0 atm
with a nominal air flow rate of 140 nm³ / h

Absolute working pressure, atm: 8
Air consumption, Nm³ / h, not more than: 140
Filter area: 250 cm²
Excessive operating pressure: no more than 8 atm
Initial pressure drop at nominal flow and size of penetrating particles:
0,06 atm → filter FPRN-0.5-KS-1-128 / P-140;
0,05 atm → filter FPRN-1,0-KS-1-128 / P-140;
0,04 atm → filter FPRN-5,0-KS-1-128 / P-140;
0,015 atm → filter FPRA-5,0-KS-1-128 / P-140;
0,015 atm → filter FPRA-10.0-KS-1-128 / P-140;
0,010 atm → filter FPRA-15.0-KS-1-128 / P-140;
0,010 atm → filter FPRA-25.0-KS-1-128 / P-140.
Final pressure drop:
not more than 1.0 atm
with a nominal air flow of 280 nm³ / h

Absolute working pressure, atm: 8
Air consumption, Nm³ / h, not more than: 280
Filter area: 540 cm²
Excessive operating pressure: no more than 8 atm
Initial pressure drop at nominal flow and size of penetrating particles:
0,06 atm → filter FPRN-0.5-KS-1-254 / P-280;
0,05 atm → filter FPRN-1,0-KS-1-254 / P-280;
0,04 atm → filter FPRN-5,0-KS-1-254 / P-280.
0,03 atm → filter FPRA-5,0-KS-1-254 / P-280;
0,03 atm → filter FPRA-10.0-KS-1-254 / P-280;
0,02 atm → filter FPRA-15.0-KS-1-254 / P-280;
0,02 atm → filter FPRA-25.0-KS-1-254 / P-280.
Final pressure drop:
not more than 1.0 atm
with a nominal air flow rate of 400 nm³ / h

Absolute working pressure, atm: 40
Air consumption, Nm³ / h, not more than: 400
Filter area: 250 cm²
Overpressure: not more than 40 atm
Initial pressure drop at nominal flow and size of penetrating particles:
0.050 atm → filter FPRN-0.5-KS-1-128 / P-400;
0.045 atm. → filter FPRN-1,0-KS-1-128 / P-400;
0.040 atm → filter FPRN-5,0-KS-1-128 / P-400;
0,03 atm → filter FPRA-5,0-KS-1-128 / P-400;
0.025 atm. → filter FPRA-10.0-KS-1-128 / P-400;
0.020 atm. → filter FPRA-15.0-KS-1-128 / P-400;
0.020 atm → filter FPRA-15.0-KS-1-128 / P-400.
Final pressure drop:
not more than 1.0 atm
with a nominal air flow of 560 Nm³ / h

Absolute working pressure, atm: 8
Air consumption, Nm³ / h, not more than: 560
Filter area: 1110 cm²
Excessive operating pressure: no more than 8 atm
Initial pressure drop at nominal flow and size of penetrating particles:
0,29 atm → filter FPRN-0.5-KS-1-508 / P-560;
0,28 atm → filter FPRN-1,0-KS-1-508 / P-560;
0,27 atm → filter FPRN-5,0-KS-1-508 / P-560;
0,27 atm → filter FPRA-5,0-KS-1-508 / P-560;
0,26 atm → filter FPRA-10.0-KS-1-508 / P-560;
0,26 atm → filter FPRA-15.0-KS-1-508 / P-560;
0,25 atm → filter FPRA-25.0-KS-1-508 / P-560.
Final pressure drop:
not more than 1.0 atm
with a nominal air flow of 800 Nm³ / h

Absolute working pressure, atm: 40
Air consumption, Nm³ / h, not more than: 800
Filter area: 540 cm²
Overpressure: not more than 40 atm
Initial pressure drop at nominal flow and size of penetrating particles:
0,100 atm → filter FPRN-0.5-KS-1-254 / P-800;
0,095 atm → filter FPRN-1,0-KS-1-254 / P-800;
0.090 atm → filter FPRN-5,0-KS-1-254 / P-800;
0,085 atm → filter FPRA-5,0-KS-1-254 / P-800;
0.080 atm. → filter FPRA-10.0-KS-1-254 / P-800;
0,075 atm → filter FPRA-15.0-KS-1-254 / P-800;
0,075 atm → filter FPRA-25.0-KS-1-254 / P-800.
Final pressure drop:
not more than 1.0 atm
with a nominal air flow of 1700 Nm³ / h

Absolute working pressure, atm: 8
Air consumption, Nm³ / h, not more than: 1700
Filter surface area: 3330 cm²
Excessive operating pressure: no more than 8 atm
Initial pressure drop at nominal flow and size of penetrating particles:
0.21 atm → filter FPRN-0.5-KS-3-508 / P-1700;
0,20 atm → filter FPRN-1,0-KS-3-508 / P-1700;
0,19 atm → filter FPRN-5,0-KS-3-508 / P-1700;
0,18 atm → filter FPRA-5,0-KS-3-508 / P-1700;
0.17 atm. → filter FPRA-10.0-KS-3-508 / P-1700;
0.17 atm. → filter FPRA-15.0-KS-3-508 / P-1700;
0,17 atm → filter FPRA-25.0-KS-3-508 / P-1700.
Final pressure drop:
not more than 1.0 atm