Filters are designed for preliminary, basic and fine cleaning of air and other gases, chemically inert to the materials of the hull and filter element, from aerosols of oil, moisture and mechanical impurities.
- Preliminary and basic gas cleaning from oil and moisture with a particle size of more than 0.3 μm:
— not less than 98%; - Fine cleaning of gases from oil and moisture with a residual content of particles larger than 0.01 μm:
— more than 99.999%.
- From the inside to the outside (for filter elements FEN / P-Pr, FEN / P-Pr 1.0 and FEN / P-T)
- 5.0 microns for FVD-P filters;
- 1.0 μm for FVD-O filters;
- 0.01 μm for FVD-T type filters.
- up to + 70 ° С
Filter element | nickel, polyurethane foam |
Housing | stainless steel |
Seals | rubber based on silicone rubbers |
- 60 nm³ / h for filters with a working pressure of 8 atm:
FVD-P-KS-1-128 / P1-60;
FVD-O-KS-1-128 / P1-60;
FVD-T-KS-1-128 / P1-60.
Replaceable filter elements:
FEN / P-Pro 5.0-128 / P1;
FEN / P-Pr 1.0-128 / P1;
FEN / P-T 128 / P1. - 140 nm³ / h for filters with a working pressure of 8 atm:
FVD-P-KS-1-128 / P1-140;
FVD-O-KS-1-128 / P1-140;
FVD-T-KS-1-128 / P1-140.
Replaceable filter elements:
FEN / P-Pro 5.0-128 / P;
FEN / P-Pr 1.0-128 / - 280 nm³ / h for filters with a working pressure of 8 atm:
FVD-P-KS-1-254 / P-280;
FVD-O-KS-1-254 / P-280;
FVD-T-KS-1-254 / P-280.
Replaceable filter elements:
FEN / P-Pr 5.0-254 / P;
FEN / P-Pr 1.0-254 / P;
FEN / P-T 254 / P.
- 560 nm³ / h for filters with a working pressure of 8 atm:
FVD-P-KS-1-508 / P-560;
FVD-O-KS-1-508 / P-560;
FVD-T-KS-1-508 / P-560.
Replaceable filter elements:
FEN / П-Пр 5,0-508 / П;
FEN / P-Pr 1.0-508 / P; - 1700 nm³ / h for filters with a working pressure of 8 atm:
FVD-P-KS-3-508 / P-1700;
FVD-O-KS-3-508 / P-1700;
FVD-T-KS-3-508 / P-1700.
Replaceable filter elements:
FEN / П-Пр 5,0-508 / П;
FEN / P-Pr 1.0-508 / P;
FEN / P-T 508 / P.
with a nominal flow rate of 60 nm³ / h

Absolute working pressure, atm: 8
Air consumption, Nm³ / h, not more than: 60
Filter area: 180 cm²
Initial pressure drop at nominal flow and size of penetrating particles:
- not more than 0,075 atm → for filters type FVD-P-KS-1-128 / P1-60;
- not more than 0.080 atm. → for filters type FVD-O-KS-1-128 / P1-60;
- not more than 0.15 atm → for filters type FVD-T-KS-1-128 / P1-60.
Final pressure drop:
- not more than 1.0 atm → for filters type FVD-P-KS-1-128 / P1-60 and FVD-O-KS-1-128 / P1-6;
- not more than 0.6 atm. → for filters type FVD-T-KS-1-128 / P1-60.
with a nominal flow rate of 140 nm³ / h

Absolute working pressure, atm: 8
Air consumption, Nm³ / h, not more than: 140
Filter area: 250 cm²
Initial pressure drop at nominal flow and size of penetrating particles:
- not more than 0.04 atm. → for filters type FVD-P-KS-1-128 / P-140;
- not more than 0.05 atm. → for FVD-O-KS-1-128 / P-140 filters;
- not more than 0,15 atm → for filters type FVD-T-KS-1-128 / P-140.
Final pressure drop:
- not more than 1.0 atm → for filters type FVD-P-KS-1-128 / P-140 and FVD-O-KS-1-128 / P-140;
- not more than 0.6 atm. → for filters type FVD-T-KS-1-128 / P-140.
with a nominal flow rate of 280 nm³ / h

Absolute working pressure, atm: 8
Air consumption, Nm³ / h, not more than: 280
Filter area: 540 cm²
Initial pressure drop at nominal flow and size of penetrating particles:
- not more than 0.04 atm. → for filters type FVD-P-KS-1-254 / P-280;
- not more than 0.05 atm. → for FVD-O-KS-1-254 / P-280 filters;
- not more than 0,15 atm → for filters type FVD-T-KS-1-254 / P-280.
Final pressure drop:
- not more than 1.0 atm. → for filters type FVD-P-KS-1-254 / P-280 and FVD-O-KS-1-254 / P-280;
- not more than 0.6 atm → for filters type FVD-T-KS-1-254 / P-280.
with a nominal flow rate of 560 nm³ / h

Absolute working pressure, atm: 8
Air consumption, Nm³ / h, not more than: 560
Filter area: 1110 cm²
Initial pressure drop at nominal flow and size of penetrating particles:
- not more than 0.27 atm → for filters type FVD-P-KS-1-508 / P-560;
- not more than 0.28 atm → for filters type FVD-O-KS-1-508 / P-560;
- not more than 0,15 atm → for filters type FVD-T-KS-1-508 / P-560.
Final pressure drop:
- not more than 1.0 atm → for filters type FVD-P-KS-1-508 / P-560 and FVD-O-KS-1-508 / P-506;
- not more than 0.6 atm. → for filters type FVD-T-KS-1-508 / P-560.
with a nominal flow rate of 1700 nm³ / h

Absolute working pressure, atm: 8
Air consumption, Nm³ / h, not more than: 1700
Filter surface area: 3330 cm²
Initial pressure drop at nominal flow and size of penetrating particles:
- not more than 0,19 atm → for filters type FVD-P-KS-3-508 / P-1700;
- not more than 0.20 atm → for filters type FVD-O-KS-3-508 / P-1700;
- not more than 0,15 atm → for filters type FVD-T-KS-3-508 / P-1700.
Final pressure drop:
- not more than 1.0 atm. → for filters type FVD-P-KS-3-508 / P-1700 and FVD-O-KS-3-508 / P-1700;
- not more than 0.6 atm. → for filters type FVD-T-KS-3-508 / P-1700.