Filters are designed for sterilizing ventilation of tanks (filter environment — air).
The efficiency of purification from particles larger than 0.01 μm: more than 99.999%.
Operating temperature: -30 to + 150 ° C
Operating pressure (excess): not more than 1 atm
Relative humidity: not more than 95%
Direction of air flow: outside — inside
Set of accessories: gasket; valve reverse (T / S) DN 50, art. 7230
- 40 nm³ / h: FSV-KS-1-252 / Rd78-40;
- 60 nm³ / h: FSV-KS-1-378 / Rd78-60;
- 85 nm³ / h: FSV-KS-1-505 / Rd78-85;
- 20 nm³ / h: FSV-KS-19-135 / Rd78-20;
- 30 nm³ / h: FSV-KS-19-202 / Rd78-30;
- 40 nm³ / h: FSV-KS-19-270 / Rd78-40;
- 60 nm³ / h: FSV-KS-19-338 / Rd78-60;
- 80 nm³ / h: FSV-KS-19-540 / Rd78-80.

Filtering surface area: 1260 cm²
Initial differential pressure at rated output:
≤ 0.0165 atm. → FSV-KS-19-135 / Rd78-20 filter
Final pressure drop at rated output:
≤ 0.6 atm → filter FSV-KS-19-135 / Rd78-20

Filtering surface area: 1960 cm²
Initial differential pressure at rated output:
≤ 0.0165 atm. → FSV-KS-19-202 / Rd78-30 filter
Final pressure drop at rated output:
≤ 0.6 atm → filter FSV-KS-19-202 / Rd78-30

Filtering surface area: 520 cm²
Initial differential pressure at rated output:
≤ 0,12 atm → filter FSV-KS-1-252 / Rd78-40
Final pressure drop at rated output:
≤ 0.6 atm → filter FSV-KS-1-252 / Rd78-40

Filter surface area: 2670 cm²
Initial differential pressure at rated output:
≤ 0.0165 atm. → FSV-KS-19-270 / Rd78-40 filter
Final pressure drop at rated output:
≤ 0.6 atm → filter FSV-KS-19-270 / Rd78-40

Filtering surface area: 810 cm²
Initial differential pressure at rated output:
≤ 0.12 atm. → FSV-KS-1-378 / Rd78-60 filter
Final pressure drop at rated output:
≤ 0.6 atm → filter FSV-KS-1-378 / Rd78-60

Filter surface area: 3380 cm²
Initial differential pressure at rated output:
≤ 0.0165 atm. → FSV-KS-19-338 / Rd78-60 filter
Final pressure drop at rated output:
≤ 0.6 atm → filter FSV-KS-19-338 / Rd78-60

Filtering surface area: 5490 cm²
Initial differential pressure at rated output:
≤ 0.0165 atm. → FSV-KS-19-540 / Rd78-80 filter
Final pressure drop at rated output:
≤ 0.6 atm → filter FSV-KS-19-540 / Rd78-80

Filtering surface area: 1100 cm²
Initial differential pressure at rated output:
≤ 0,12 atm → filter FSV-KS-1-505 / Rd78-85
Final pressure drop at rated output:
≤ 0.6 atm → filter FSV-KS-1-505 / Rd78-85