Автономные источники тока на базе твердооксидных топливных элементов
Fuel cells

They are intended for power supply and heat supply to gasified autonomous objects remote from grid power supply to the cathodic protection station and infrastructure facilities of the gas transmission system, mobile communication repeaters, emergency and uninterrupted power supply systems, and other facilities.

The energy block consists of three main parts:

  • SOFC power plants
  • container block
  • the reduction block.
  • high efficiency (total to 90% in cogeneration mode);
  • ecological purity (on the alkaline fuel cells the reaction product is water, and on SOFC — water and carbon dioxide);
  • generation of high-potential heat;
  • heating for 3,5 hours;
  • high reliability and stability to emergency situations;
  • modularity and simplicity of design;
  • maximum universality by types of gasified fuel;
  • minimum maintenance requirement (once a year);
  • no need to supply formogen gas when heated;
  • the possibility of organizing autonomous operation.
  • rated electric power: 2 kW;
  • power consumption of control electronics: 0,4 kW;
  • rated output electric power: 1.6 kW;
  • maximum thermal power: 3.5 kW;
  • resource of work: not less than 5 years;
  • Methane consumption: 0.44 m³/kWh;
  • output voltage: 220 V, 50 Hz.
Fuel cells 250W power Sample
Образец энергоустановки на основе ТОТЭ мощностью 250 Вт

Specifications:

  • the nominal electric power generated is not less than 250 W;
  • coefficient of efficiency (the ratio of generated electric power to the net calorific value of fuel) is not less than 15%, taking into account own needs;
  • fuel utilization factor — not less than 0.8;
  • Rated fuel consumption in operating mode, reduced to nos. — no more than 0,2 m³ / h;
  • the current is constant;
  • output voltage of direct current — (20 ÷ 29.5) V;
  • climatic performance U 1;
  • weight and dimensions: 2000 × 2100 × 800 mm, not more than 1500 kg.
Fuel cells 500W power Sample
Образец энергоустановки на основе ТОТЭ мощностью 500 Вт

Specifications:

  • the rated electric power generated is not less than 500 W;
  • coefficient of efficiency (ratio of generated electrical power to the net calorific value of fuel) — not less than 16%, taking into account own needs;
  • fuel utilization factor — not less than 0.8;
  • Rated fuel consumption in operating mode, reduced to nos. — no more than 0,3 m³ / h;
  • the current is constant;
  • output voltage of direct current — (20 ÷ 29.5) V;
  • climatic performance U 1;
  • weight and dimensions: 2000 × 2100 × 800 mm, not more than 1500 kg.